Switches

Configuring the ICX-250

21

 

The bold highlighted selection under “Options” is the Factory Setting.

 

 

 

 

 

 

 

 

 

Function

Switch

Switch

Option

Description

 

 

Location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FXS Ports

S14, S15, S16

Internal

3 dB

3 dB: Transmit path attenuated by

 

 

Transmit

positions 2, 4, 6

 

9 dB

3 dB (+/– .5).

 

 

for 12 port model

and 8

 

 

9 dB: Transmit path attenuated by

 

 

(see page 26)

 

 

 

9 dB (+/– .5).

 

 

 

 

 

 

 

 

 

FXS Ports

S14, S15, S16

Internal

3 dB

3 dB: Receive path attenuated by

 

 

Receive

positions 1, 3, 5

 

9 dB

3 dB (+/– .5).

 

 

for 12 port model

and 7

 

 

9 dB: Receive path attenuated by

 

 

(see page 26)

 

 

 

9 dB (+/– .5).

 

 

 

 

 

 

 

 

 

FXS Ports

S17, S18, S19

Internal

3 dB

3 dB: Transmit path attenuated by

 

 

Transmit

positions 2, 4, 6

 

9 dB

3 dB (+/– .5).

 

 

for 24 port model

and 8

 

 

9 dB: Transmit path attenuated by

 

 

(see page 26)

 

 

 

9 dB (+/–.5).

 

 

 

 

 

 

 

 

 

FXS Ports Receive

S17, S18, S19

Internal

3 dB

3 dB: Receive path attenuated by

 

 

for 24 port model

positions 1, 3, 5

 

9 dB

3 dB (+/– .5).

 

 

(see page 26)

and 7

 

 

9 dB: Receive path attenuated by

 

 

 

 

 

 

9 dB (+/– .5).

 

 

 

 

 

 

 

 

 

Trunk Conditioning

S6, S7

Internal

Idle

Idle: In the event of an alarm condi-

 

 

(per group of 12

position 6

 

Idle Imm./Busy

tion in the T1 connection to the net-

 

 

lines)

 

 

 

work, the FXS Ports will be put into

 

 

(see page 28)

 

 

 

the idle state immediately and

 

 

 

 

 

 

remain in this condition until the T1

 

 

 

 

 

 

has been restored.

 

 

 

 

 

 

Idle Immediate/Busy: In the event

 

 

 

 

 

 

of an alarm condition in the T1 con-

 

 

 

 

 

 

nection between the ICX-250 and

 

 

 

 

 

 

the network, the FXS Ports will be

 

 

 

 

 

 

put into the Idle state immediately

 

 

 

 

 

 

for 3 seconds and then put in the

 

 

 

 

 

 

Busy state and remain in this condi-

 

 

 

 

 

 

tion until the T1 has been restored.

 

 

 

 

 

 

 

 

 

FXS Ringback Tone

S6-S7

Internal

On

On: Ringback tones will be sent

 

 

(see page 29)

position 7

 

Off

on the corresponding DS0’s for the

 

 

 

 

 

 

duration of ringing on the line.

 

 

 

 

 

 

Off: Ringback provided by PBX

 

 

 

 

 

 

or Switch.

 

 

 

 

 

 

 

 

 

FXS Timeslot

S7 Only

Internal

Off

Off: FXS Ports 1-12 are mapped

 

 

Assignment

position 8

 

Swap

onto T1 timeslots 1-12 and FXS

 

 

(see page 30)

 

 

 

Ports 13-24 are mapped onto T1

 

 

 

 

 

 

timeslots 13-24.

 

 

 

 

 

 

Swap: FXS Ports 1-12 are mapped

 

 

 

 

 

 

onto T1 timeslots 13-24 and FXS

 

 

 

 

 

 

Ports 13-24 are mapped onto T1

 

 

 

 

 

 

timeslots 1-12.

 

 

 

 

 

 

Depending on the services pro-

 

 

 

 

 

 

vided by your carrier for voice

 

 

 

 

 

 

and data, you may need to reas-

 

 

 

 

 

 

sign the FXS timeslots of the 12

 

 

 

 

 

 

FXS port model. Timeslots 13 to

 

 

 

 

 

 

24 will be assigned in order to

 

 

 

 

 

 

allocate data to the lower

 

 

 

 

 

 

timeslots.

 

 

 

 

 

 

 

 

 

FXS Ports

S4-S5

Back

On

On: Breaks the connections to

 

 

Loopback Operation

S5 1-12 = 1-12

 

Off

and from the FXS and loops the

 

 

and/or Channel

S4 1-12 = 13-24

 

 

receive data back onto the transmit

 

 

Unassigned

 

 

 

path towards the T1. In the case

 

 

(per line)

 

 

 

 

 

 

 

 

of unassigned channels, provides

 

 

(see page 39)

 

 

 

 

 

 

 

 

an idle termination.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Issue 1, September 1998

 

 

 

ADCP-62-023

© 1998, ADC Telecommunications, Inc.