Switches

Configuring the ICX-250

25

!!ATTENTION!! Changing the Supervision type switches will result in all FXS calls on the affected 12 FXS line group to be reset to the idle state each time a DIP switch setting is changed. This means any active

calls in that FXS line group will be dropped.FXS Supervision Table

(Mode)

1, 2

 

 

3, 4, 5 (Type)

 

 

000

001

100

 

101

110

 

 

 

 

 

 

 

 

 

 

 

 

FXS

00

LS

LS-fd

 

GS

 

GSa

GSi

 

 

 

 

 

 

 

 

 

FXS-DN

01

LS

LS-fd

 

GS

 

GSa

GSi

 

 

 

 

 

 

 

 

 

FXS-DN-WINK

10

LS

LS-fd

 

GS

 

GSa

GSi

 

 

 

 

 

 

 

 

 

TR-08

11

SP

---

 

UVG

 

UVGa

---

 

 

 

 

 

 

 

 

 

Legend: (e.g. S1 position 5 = 01001 means Mode = FXS-DN / Type = LS-fd)

LS = Loop Start

LS-fd = Loop Start-Forward Disconnect

GS = Ground Start

GSa = Ground Start Automatic

GSi = Ground Start Immediate

SP = Single Party

UVG = Universal Voice Grade

UVGa = Universal Voice Grade Automatic

Issue 1, September 1998

ADCP-62-023

© 1998, ADC Telecommunications, Inc.