Connector Type

Electrical Installation

45

Connector PinoutsDCE DB25 Female Connector (Data Ports 1 and 2)

 

Pin

Signal

Name

Mnemonic

Source

V.35

EIA-530A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Shield

 

 

 

 

X

 

 

2

Transmit Data

TXD+

BA (A)

DTE

X

X

 

 

 

 

 

 

 

 

 

 

 

3

Receive Data

RXD+

BB (A)

DCE

X

X

 

 

 

 

 

 

 

 

 

 

 

4

Request to Send

RTS+

CA (A)

DTE

X

X

 

 

 

 

 

 

 

 

 

 

 

5

Clear to Send

CTS+

CB (A)

DCE

X

X

 

 

6

DCE Ready

DSR+

CC

DCE

X

X

 

 

 

 

 

 

 

 

 

 

 

7

Signal Common

 

AB

 

X

X

 

 

 

 

 

 

 

 

 

 

 

8

Receive Line Signal Detector

DCD+

CF (A)

DCE

X

X

 

 

 

 

 

 

 

 

 

 

 

9

Receive Signal Element Timing

RXCLK-

DD (B)

DCE

X

X

 

 

10

Receive Line Signal Detector

DCD-

CF (B)

DCE

 

X

 

 

11

Transmit Signal Element Timing (DTE)

TXCLK

DA (B)

DTE

 

X

 

 

 

 

 

 

 

 

 

 

 

12

Transmit Signal Element Timing (DCE)

TXCLK-

DB (B)

DCE

X

X

 

 

 

 

 

 

 

 

 

 

 

13

Clear to Send

CTS-

CB (B)

DCE

 

X

 

 

 

 

 

 

 

 

 

 

 

14

Transmit Data

TXD-

BA (B)

DTE

X

X

 

 

15

Transmit Signal Element Timing (DCE)

TXCLK+

DB (A)

DCE

X

X

 

 

 

 

 

 

 

 

 

 

 

16

Receive Data

RXD-

BB (B)

DCE

X

X

 

 

 

 

 

 

 

 

 

 

 

17

Receive Signal Element Timing (DCE)

RXCLK+

DD (A)

DCE

X

X

 

 

 

 

 

 

 

 

 

 

 

18

Local Loopback

LL

LL

DTE

 

X

 

 

19

Request to Send

RTS-

CA (B)

DTE

 

X

 

 

 

 

 

 

 

 

 

 

 

20

DTE Ready

DTR+

CD

DTE

 

X

 

 

 

 

 

 

 

 

 

 

 

21

Remote Loopback

RL

RL

DTE

 

X

 

 

 

 

 

 

 

 

 

 

 

22

Ring Indicator

 

CE

DCE

 

X

 

 

23

Signal Common

 

AC

 

 

X

 

 

 

 

 

 

 

 

 

 

 

24

Transmit Signal Element Timing (DTE)

TXCLK

DA (A)

DCE

 

 

 

 

 

 

 

 

 

 

 

 

 

25

Test Mode

TM

TM

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: For purposes of connection and function, the ICX-250 should be considered a DCE.

Issue 1, September 1998

ADCP-62-023