Agilent Technologies 90B manual DC Distribution Terminals, Improper Load Connections

Models: 90B

1 125
Download 125 pages 25.51 Kb
Page 61
Image 61

Figure 34. Improper Load Connections

DC Distribution Terminals

A single pair of terminals are designated as the positive and negative "DC Distribution Terminals" (DT's). These two terminals may be the power supply output, the B+ at the load, or a separate pair of terminals established expressly for distribution. Proper location of the DT's results in improved over-all performance and reduced mutual coupling effects between separate loads using the same power supply. If remote sensing is not used, locate the DT's as close as possible to the power supply output terminals - optimum performance will result when the power supply output terminals themselves are used as the DT's. (See Figure 35.)

Figure 35. Location of DC Distribution Terminals Remote Sensing

62

Page 61
Image 61
Agilent Technologies 90B manual DC Distribution Terminals, Improper Load Connections