Manuals
/
Agilent Technologies
/
Power Tools
/
Stud Sensor
Agilent Technologies
E9300
manual
Operating and Service Guide
Models:
E9300
1
1
71
71
Download
71 pages
61.87 Kb
1
2
3
4
5
6
7
8
<
>
Troubleshooting
Specs
Spread Spectrum Signal
Warranty
Connector Type
Reassembly Procedure
Auto-averaging Settings
Cleaning
Safety
Power Meter Requirements
Page 1
Image 1
Operating and Service Guide
Agilent Technologies
E-Series
E9300 Power Sensors
Agilent Technologies Part no.
E9300-90016
January 1999
Page 2
Page 1
Image 1
Page 2
Contents
Operating and Service Guide
Copyright 1999 Agilent Technologies
Legal Information
Warranty
Certification
Exclusive Remedies
Limitation of Warranty
Sound Emission
General Safety Information
Power Meter Front Panel Operation
Safety
Conventions
Sensors Covered by Manual
Documentation
Related Publications
Documentation
Table of Contents
Standing Wave Ratio SWR and Reflection Coefficient Rho Per
Introduction
Typical HP E-series E9300 power sensors
General Information
Power Meter Requirements
Simplified Block Diagram of Diode Pair/Attenuator/Diode Pair
Agilent E-Series E9300 Power Sensors in Detail
General Information
Getting Started
Checking Power Meter Firmware and DSP Revision
Initial Inspection
Interconnections and Calibration
Specifications
Making Measurements
What You’ll Find This Chapter
Auto-averaging Settings
Power Meter Configuration Changes
Spread Spectrum Signal
Measuring Spread Spectrum and Multitone Signals
Cdma IS-95A 9Ch Fwd
Cdma Signal Measurements
90 % Frequency GHz Typical Lower Range Calibration Factor
Multitone Signal Measurements
Power Meter and Sensor Operation
Measuring Tdma Signals
Achieving Stable Results with Tdma Signals
Input Settings , More
Achieving Stable Results with GSM Signals
Electromagnetic Compatibility EMC Measurements
Measurement Accuracy and Speed
Setting the Range
Accuracy
Measurement Considerations
Summary
Speed and Averaging
Specifications and Characteristics
Introduction
Sensor Low Power Path High Power Path
Connector Type
E9300/1/4/A Power Sensor Specifications
Maximum SWR
0C to +55C
Maximum DC Voltage
Maximum Power
± 2.5%
Power Linearity
Typical Power Linearity at 25C, after zero
Additional Power
Zero Set Zero Drift Measurement Noise
Switching Point
Time E4418B E4419B
Settling Time
Calibration Factor and Reflection Coefficient
X2 Mode
Cal Factor Uncertainty
General
Frequency Range
E9300/1B and H Power Sensor Specifications
E9300B Typical SWR 25C ± 10C
E9300H Typical SWR 10 MHz to 18 GHz 25C ± 10C
Maximum Power Sensor To 35 C To 55 C GHz
E9300/1B To 0 dBm To 10 dBm 10 to 20 dBm 20 to 26 dBm
For larger changes refer to the following table
E9300/1H DBm to 0 dBm
+44 +30 dBm
E9300/1B Conditions Zero Set Zero Drift2 Measurement
Settling Time
Typical
Cal Factor Uncertainty Low Power Path
Cal Factor Uncertainty High Power Path
Storage and Shipment Environment
References
E9300/1B and H Power Sensor Specifications
Service
Connector Cleaning
Cleaning
Frequency System Rho Actual Maximum Uncertainty Measurement
Performance Test
Performance Test
Is the illustrated parts breakdown IPB that identifies all
Replaceable Parts
Illustrated Parts Break down
Reference Agilent Part Qty Description Designation Number
LABEL, ID E9301B
Principles of Operation
Service
Disassembly Procedure
Troubleshooting
Repair of Defective Sensor
Removing Power Sensor Shell
Reassembly Procedure
Asia Pacific
Sales and Service Offices
Europe
Top
Page
Image
Contents