Allied Telesis AT-iMG646PX-ON, AT-EN646 manual Section I Outdoor Installation

Models: AT-iMG646PX-ON AT-EN646

1 98
Download 98 pages 34.36 Kb
Page 31
Image 31

AT-iMG646xx Series Intelligent Multiservice Gateway and AT-EN646 Enclosure Installation Guide

All installation methods shall be in accordance with national and local regulations and practices. The wiring method should include the use of Listed wire/cable acceptable for the application per the National Code, and should be one that an Authority Having Jurisdiction (AHJ) can approve per the Code.

No wiring to the product should be exposed in lengths beyond 140 feet, as circuits should avoid exposure to accidental contact with lightning and power conductors in accordance with NEC Article 725-57 (NEC 2002). The installer should also consider Articles 210, 240, 250, 770 and 810 of the National Electrical Code (NEC).

The pluggable external power supply provided with the unit should be mounted indoors. If other power supplies are employed, they should be LISTED ITE with a Limited Power Source (PLS) output, LISTED with an NEC Class 2 output, or another NEC Class 2 source of power compliant with Article 725.

Section I: Outdoor Installation

31

Page 31
Image 31
Allied Telesis AT-iMG646PX-ON, AT-EN646 manual Section I Outdoor Installation