Appendix C

Turnup Process

The AT-iMG646 family of intelligent Multiservice Gateways are shipped with both a main software image and a recovery software image. The recovery software image is used in the case where the main image is corrupted during download, for example, if the power is disconnected during a software download. A default configuration file shipped on the AT-iMG646 gateway instructs it to send a DHCP request on an untagged VLAN and download a configuration file. The configuration file downloaded from the network server includes information on the desired recovery software and main software load. On bootup, the gateway checks the stored configuration, downloads the network specific configuration file, and upgrades both the recovery and main software load. The power up and upgrade sequence is detailed in a separate turnup document. Please contact your Allied Telesis sales representative for more information.

The gateway bootup sequence is:

ˆNormal power up sequence

ˆUpgrade the recovery software image (if required)

ˆUpgrade the main software image (if required)

ˆNMS services provisioning

This process is also shown in the flowchart on the next page.