Allied Telesis AT-EN646, AT-iMG646PX-ON manual Installing Armored Drop Cable

Models: AT-iMG646PX-ON AT-EN646

1 98
Download 98 pages 34.36 Kb
Page 40
Image 40

Chapter 3: Installing the Enclosure

Installing the

Armored Drop

Cable

3.Wrap the tracer wire around the base of the post under the washer. Wrap the aramid yard around the post at least four times, just above the tracer wire and under the washer, and tighten the nut, as shown in Figure 12.

Aramid Yarn

Tracer Wire

847

Figure 12. Securing the Tracer Wire and Aramid Yarn

4. Trim the yarn back to the post.

To install the armored drop cable, perform the following procedure:.

All Countries: Install product in accordance with local and National Electrical Codes.  E8

1.Locate the fiber optic drop cable and ground wire entrance on the enclosure, as shown in Figure 7.

843

Fiber Optic Drop Cable and Ground Wire Enclosure Entrance

Figure 13. Location of Fiber Optic Drop Cable and Ground Wire Entrance

2.Route the fiber optic drop cable to the enclosure entrance and mark the entrance location on the cable.

3.Cut the cable 42 in. (106.7 cm) beyond the mark.

40

Section I: Outdoor Installation

Page 40
Image 40
Allied Telesis AT-EN646, AT-iMG646PX-ON manual Installing Armored Drop Cable