Chapter 5: Installing the Gateway Indoors
Preparing and Connecting the Power Cord
The
Allied Telesis provides a 15 ft. power cord (part number
Caution
To properly ground the unit, you MUST install a terminal block ground wire as described in this procedure. The materials needed for the terminal block ground wire are described in “Additional Supplies” on page 72.
To prepare and connect the power cord, perform the following procedure:
Warning
Ensure that the UPS is OFF before you perform this procedure.
1.Connect the wires in the power cord to the DC terminal block in the accessory kit (the wiring diagram is shown in Appendix A) at 4.5
Caution
To prevent electrical shock, ensure that the power cord is not connected to the UPS.
2.Cut a piece of insulated #18 AWG stranded wire to
3.Strip 1/4 in. (6 mm) of insulation from both ends.
4.Slide a #10 ring lug with a green insulation jacket onto one end of the wire and double crimp.
5.Twist the strands on the other end of the wire into a tight bundle.
78 | Section II: Indoor Installation |