AT-iMG646xx Series Intelligent Multiservice Gateway and AT-EN646 Enclosure Installation Guide

Figure 40, cut a 1/4” “X” in it, and put it back in place.

Connecting the LAN Cables

859

Telephone Wire Entrance

Figure 40. Telephone Wire Entrance

2.Slip the telephone wire through the grommet.

3.Connect the telephone wires to each pair of telephone terminal posts in the enclosure, as shown in Figure 41, at 5.3 in-lbs.

Figure 41. Connecting the Telephone Wires

4.Secure the telephone wire to the entrance with a UV-rated wire tie (not provided).

5.Seal the grommet with electrical tape (not provided) and silicone sealant (not provided).

To connect the LAN cables, perform the following procedure:

Note

Allied Telesis recommends that you fully wire all six ports to allow for easy service expansion in the future.

Section I: Outdoor Installation

63

Page 63
Image 63
Allied Telesis AT-iMG646PX-ON, AT-EN646 manual Connecting the LAN Cables