Chapter 4: Installing the Gateway Outdoors

Caution

To prevent shorting out the unit, ensure that no wires are sticking out from pin 5.

11.Pull on both wires at pin 5 to ensure that they are securely fastened to the terminal block.

12.Plug the other end of the power cord into the UPS.

Caution

DO NOT plug the terminal into the unit until after you have completed the verification process in the following step.

13.Verify the resistance of the ground wire using a Digital Multimeter.

Measure the resistance between the pin 5 screw on the terminal block and the top of the ground wire post. The resistance must be below 0.1 ohm. If it is not, disconnect the power cable, repeat steps 8 through 11, and re-test.

14.Plug the terminal block into the DC power socket, as shown in Figure 36.

Mounting the Splice Tray on the Gateway

859

Figure 36. Plugging in the DC Terminal Block

15. Seal the grommet with silicone sealant.

To mount the splice tray to the gateway, perform the following procedure:

1.Remove the splice tray from its temporary position on the inside of the inner cover.

2.Do one of the following:

ˆ For a metal splice tray, position the splice tray on the four standoffs

60

Section I: Outdoor Installation