![VE NTL ESS HOOD](/images/new-backgrounds/69026/6902673x1.webp)
VE NTL ESS HOOD
UNPA CK ING | & |
| |
|
| ||
The | Ventless Hood has been thoroughly tested and inspected to ensur e only the highes t quality | ||
unit is provid ed. | When you rece ive your hood, che ck for any possible shipping damage and report it at once | ||
to the deliv ering | car rier. |
| |
Save all the inf ormatio n and instructions packed ins ide the cart on. | Comple te and return the warra nty card | ||
to the factory as soon as possible to assure prompt service in the event | of a warranty parts and labor claim. |
NOTE: All claim s for war ranty must include the full model number and serial numbe r of the hood.
EL EC TRI CAL CONN EC TI ON
1. An identif ica tion tag is permanentl y mounted on the base of the unit.
2. The inte rconnect cord from the ventless hood to the rotisserie oven provide s full power conne ctio n.
HOOD OPERATI ON
VEN TLE SS HOO D CONTRO L
ON/OFF SWITCH
FAN INDICATOR LIGHT
Illuminates when fan is running.
RESET BUTTON Press after correction of any problem with hood or oven.
The Ventless Hood is factory installe d directly on the top of the Alto
Turn the ventle ss hood ON before operat ing the rotisserie oven. There are a number of safety features inco rporated into the operation of the hood which are dire ctly related to the interaction of hood funct ion and the operation of the rotisserie oven.
VENTLE SS HOOD INTERLOCK SWITCH ES
—CHARCOAL FILTER SWITCH GREASE FILTER SWITCH
Prevents both hood and oven operation if any filte r is not in plac e or is improperly installed.
—FAN PRESS URE SWIT CH: Prevent s rotiss erie oven operation if hood fan is not operating or if the filt ers are more than 25% blocked.
RESET SWITCH
—The Reset has to be used if the rotisserie oven is turned on before the hood or if the hood was opened. It reset s the pressu re switch circuit and provides power to the rotisseri e control circuit. This switch must also be used to reset hood controls after any problem with the filters. See illustrations on following pages of this manual.
NO TE : If the filte rs are dirt y or in need of repla cemen t the hood will not res et and the roti sse rie will not operate until they have been clea ned and/or repla ced.