OP E R ATI ON
PROG RAM OP TIONS
SELECTION SCRE EN
Star ting from the position , press the power key . The
to opera te if requi red by the sensors.
1x.
2x.
3x.
4x.
Press the PROGRAM key. The display | wil l indicate | all of the following Quic kchiller operati ng | |||||||
parameter s each time the | Progra m key is presse d. |
|
|
| |||||
The displa y will indicate a choice |
| 5x . | The display will indicate the | ||||||
betwe en Celsius and Fahrenheit for |
|
|
| Communications Address Number. | |||||
Quickchiller temperature display |
|
|
| This item allows the operator to | |||||
read ings. Press the up or down |
|
|
| assign a specific identifying number | |||||
arrow key to toggle the |
|
|
| to the individual Quickchiller as part | |||||
measurement. |
|
|
| of a serial communication interfa ce | |||||
The displa y will indicate a |
|
|
| for the | |||||
|
|
| Kitchen Management software | ||||||
MANUAL DEFROST screen. |
|
|
| package option. |
|
|
| ||
Press the START/STOP key |
| 6x . | The display will indicate the Select | ||||||
to initiat e a manual defrost |
|
|
| Language screen. Press the right | |||||
cycle. The defrost cycle will |
|
|
| or leftarrow key to sel ect English, | |||||
complete operation when the |
|
|
| Spanish, or French as the language | |||||
temperature of the coil or |
|
|
| of choi ce. |
|
|
|
| |
coils reach |
|
|
| The disp lay will | indica te |
|
| ||
after a period of 20 minutes, |
| 7x . |
|
| |||||
whichever occurs first . |
|
|
| “END PROGRAMMABLE |
|
| |||
The displa y will indicate the leng th |
|
|
| OPTIONS” screen . |
|
| |||
|
| Unless oth erw ise noted, press |
|
| |||||
of time nec essary to accrue before |
|
|
|
| |||||
the Fan Time r triggers an aut omat ic |
|
| START/STOP | at any time to exit the | |||||
defrost cyc le. This perio d of time |
|
| Progr am screen and retu rn to the | ||||||
can be adjus ted by pressing the |
|
| SELECTIO N SCRE EN. |
|
| ||||
right or leftarrow keys to select |
|
|
|
|
|
|
|
|
|
betwe en hou rs or min utes and the |
|
|
|
|
|
|
|
|
|
up or down arrow key to |
| The | Quickchi ller will | only | trigger an | automatic |
| ||
increase or decrease automat ic |
|
| |||||||
defrost cyc le time. |
| defrost cycle during the refrige rated Hold Temp |
| ||||||
| mode. If the chiller is in any other mode when the |
| |||||||
The displa y will indicate DATE, |
| Fan | Timer lim it plus | one | additional | hour has |
| ||
| elapsed, | the display | wil l | indicate a | warni ng |
| |||
TIME, and DAY OF WEEK. Press |
| message “DEFROST OVERDUE” every 10 seconds |
| ||||||
the right or leftarrow key to |
| until | a | defrost is conducted. | A defrost can be |
| |||
select the date, time , and day, and |
| initi ated | manually as indicated in step 2 shown |
| |||||
the up or down arrow key to |
| above or by allowing the Quickch iller to enter the |
| ||||||
increase or decrease the numbe rs |
| Hold Temp mode. |
|
|
|
|
| ||
as required. |
|
|
|
|
|
|
|
|
|
QUI CKCHI LLER • IN STAL LATI ON /OP ER ATI ON /S ERV IC E MA NUAL • 22 .