![TIM E If time was se lect ed …](/images/new-backgrounds/69399/6939935x1.webp)
O PERATIO N
H A R D C H I L L
TIM E If time was se lect ed …
The display will indica te the last period of time set by the operator. To change the disp layed time, press the right or leftarrow keys to sele ct between hours or minutes and the up or down arrow key to increase or decreas e the time.
Pres s the START/STO P key.
The Disp lay wil l ind icate the las t set hol ding tempe ratu re.
To chang e the displayed temperat ure press the up or down arrow key to increase or dec rease the temperatu re displa y to any point within Qui ckchi ller paramete rs for chillin g product .
After selectio ns have bee n made, press the STAR T/S TOP key. The Quic kchiller will begin opera ting in the Hard Chill “time” mode.
When chilling by time , the display wil l ind icat e a cou
PROBE If pr obe was sel ect ed …
The display will indic ate the last tempe rature set by the operat or for each prob e. To change the displa yed prob e temperatur e(s) , press the rig ht or left arrow keys to selec t each prob e and the up or down arrow key to increas e or dec rease probe temperatu re.
Press the START/STOP key.
The Dis play will ind icate the last set holdi ng temp erat ure.
To chang e the displayed | temperat ure press the up or down | arrow key to increase or dec rease the temperatu re |
displa y to any | poi nt within Qui ckchi ller parameters | for chi lling produc t. |
After selectio ns have bee n made, press the STAR T/S TOP key.
The Quick chiller will begin ope rati ng in the Hard Chi ll “probe” mode . When chill ing by probe , the displ ay wil l indic ate the len gth of time the produ ct has been in the Hard Chill mode, the interi or compa rtme nt set temp era ture, and the air temp erat ure . The displ ay will als o indi cat e the temp erat ure of each prob e along with “ACT.” to advise the operato r that the individual probe is acti ve. As each probe reache s the set point value, the displa y will indi cate “DONE.” When all probes reach the individ ual set point value, the chill er will automa tica lly con vert to the holdi ng mode for chilled produ ct.
| Press the RIGHT or LEFTarrow key to display the length of time it took for each probe to achieve set temperature. | ||
| WHEN IN THE HOLD TEMP MODE AFTER HARD CHILLING | BY PROB E: |
|
| TH ESE DATA ARE RETAINED UNTIL A NEW PROBE | CYCLE IS COMPLETED . | |
|
|
|
|
QUI CKCH IL LER • IN STAL LA TIO N/ OP ER ATI ON /SE RV IC E MA NUAL • 17 .