INS TALLATIO N
ELECTR I CAL
DA NGE R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCEWITH
APPLICABLE ELECTRICAL CODES.
|
|
|
|
|
|
|
| |
VOLTAGE | PHASE | CYCLE /HZ | QC | QC - 20 | QC- 40 | QC- 50 | QC- 10 0 | |
50/60 Hz |
|
|
|
|
| |||
1 ph | 20 amps | 20 amps | 30 amps | 40 amps | 60 amps | |||
RECOM MENDED CIRC UIT AMPERAGE : | ||||||||
| RECO MMENDE D WIRE SIZE: | 12/2 w.g. | 12/2 w.g. | 10/2 w.g. | 8/2 w.g. | 6/2 w.g. | ||
|
|
|
| NO C O R D A N D P L U G |
|
| ||
|
|
|
|
|
|
|
| |
VOLTAGE | PHASE | CYCLE /HZ | QC | QC - 20 | QC- 40 | QC- 50 | QC- 10 0 | |
50/60 Hz |
|
|
|
|
| |||
3 ph | NOT AVAILAB LE | NOT AVAILABLE | NOT AVAILABLE | 20 amps | 40 amps | |||
RECOM MENDED CIRC UIT AMPERAGE : | ||||||||
| RECO MMENDE D WIRE SIZE: |
|
|
| 12/3 w.g. | 8/3 w.g. | ||
|
|
|
| NO C O R D A N D P L U G |
|
| ||
|
|
|
|
|
|
|
| |
VOLTAGE | PHASE | CYCLE /HZ | QC | QC - 20 | QC- 40 | QC- 50 | QC- 10 0 | |
REMOTE | COMPRESSOR |
|
|
|
|
| ||
(Cabinet | Only) | 50/60 Hz |
|
|
| 20 amps | 30 amps | |
1 ph | NOT AVAILAB LE | NOT AVAILABLE | NOT AVAILABLE | |||||
RECOM MENDED CIRC UIT AMPERAGE : |
|
|
| 12/2 w.g. | 10/2 w.g. | |||
| RECO MMENDE D WIRE SIZE: |
|
|
|
|
|
NO C O R D A N D P L U G
DA NGE R
ENSURE POWER SOURCE
MATCHESVOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
QUI CKCHI LLER • IN STAL LA TIO N/O PE RA TIO N/ SE RVI CE MANUA L • 7 .