Connections and Wiring

3.Remove the rear panel from the device, and then disconnect the NXI control cable and remove the Master card.

4.Locate the battery behind the Configuration Port on the circuit board.

5.Carefully slide the battery out of its socket and insert the new battery.

6.Plug the 2-pin 3.5 mm mini-Phoenix PWR (green) connector to reapply power. Wait approximately 1 minute, then remove the PWR connector again.

7.Carefully slide the other battery out of its socket and insert the new battery

8.Re-connect the NXI control cable to the Master card.

9.Replace and secure the rear faceplate using the mounting screws and reconnect all communication connectors.

10.Reconnect the 12 VDC power supply to the respective PWR connector and apply power.

CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS

NI-3101-SIG Signature Series NetLinx Integrated Controller

15

 

 

Page 25
Image 25
AMX NI-3101-SIG manual Connections and Wiring