NetLinx Security within the Web Server

Valid Level Data Types and Ranges

 

Minimum Value

Maximum Value

 

 

 

CHAR

0

255

 

 

 

INTEGER

0

65535

 

 

 

SINTEGER

-32768

32767

 

 

 

LONG

0

429497295

 

 

 

SLONG

-2147483648

2147483647

 

 

 

FLOAT

-3.402823466e+38

3.402823466e+38

 

 

 

11.Within the Command and String fields, you can enter any number of messages that can be sent as either a String or Command.

12.To Emulate sending a String or Command, type a String or Command within the corresponding field and press the Send button to transmit this data.

When entering a send command (in the context of this dialog) do not include the "send c" or "send_command" in the statement - only type what would normally occur within the quotes, but don't include the quotes either. For example to send the "CALIBRATE" send command, simply type CALIBRATE (no quotes) rather than SEND_COMMAND <dev> "CALIBRATE".

String Expressions start and end with double quotes (" "). Double quotes are not escaped; instead, they are embedded within single quotes. String expressions may contain string literals, decimal numbers, ASCII characters and hexadecimal numbers (prepended with a $), and are comma-delimited.

String Literals start and end with single quotes ( ' ). To escape a single quote, use ''' (three single quotes).

Manage System - Diagnostics

This page allows an authorized user to setup and monitor diagnostic messages coming from and going to devices available on the Online Tree. This dialog also allows the user to watch the ICSP commands being sent to/from a device. There are several different types of asynchronous notifications that can be selected for a device:port:system (D:P:S) combination. Each notification type is represented by a column in the table. All messages are displayed in the Notifications tab of the Output Display window within NetLinx Studio v 2.4.

1.Click the Manage System link (from within the System Settings section of the Navigation frame).

2.Clicking on any of the Online Tree items opens menu items with the Diagnostics button option available.

3.Click the Diagnostics button to open the Diagnostics dialog (FIG. 48).

4.Use the Refresh Interval drop-down to select from the following values: 2 seconds, 5 seconds, or 10 seconds. This refresh interval allows you to select how often the messages are updated.

NI-3101-SIG Signature Series NetLinx Integrated Controller

57

 

 

Page 67
Image 67