NetLinx Security within the Web Server

1.Click on the Create User Defined Device button (from within the Manage Other Device page).

2.Begin by entering the address of the physical device within the Address field. This information can be either the NetLinx Master port value (D:P:S) or an IP Address (#.#.#.#).

3.From within the Device Category field, use the drop-down list to select the control method associated with the physical target device (IR, IP, Serial, Relay, Other).

4.From within the SDK Class field, use the drop-down list to select the closest Device SDK class type match for the physical target device. The following table provides a listing of the available choices.

SDK-Class Types

Amplifier

DocumentCamera

SlideProjector

 

 

 

AudioConferencer

HVAC

Switcher

 

 

 

AudioMixer

Keypad

Text Keypad

 

 

 

AudioProcessor

Light

TV

 

 

 

AudioTape

Monitor

Utility

 

 

 

AudioTunerDevice

Motor

VCR

 

 

 

Camera

MultiWindow

VideoConferencer

 

 

 

Digital Media Decoder

PoolSpa

VideoProcessor

 

 

 

Digital Media Encoder

PreAmpSurroundSoundProcessor

VideoProjector

 

 

 

Digital Media Server

Receiver

VideoWall

 

 

 

Digital Satellite System

Security System

VolumeController

 

 

 

Digital Video Recorder

Sensor Device

Weather

 

 

 

Disc Device

SettopBox

 

 

 

 

5.Use the GUID field to enter the manufacturer-specified device’s Global Unique Identification information. Either the GUID or Make/Model must be specified within this field.

6.Enter the name of the manufacturer for the device being used (up to 55 alpha-numeric characters) (ex: Sony, ONKYO, etc.) into the Make field. Either the GUID or Make/Model must be specified within this field. Note that spaces in the name will be converted to underscores.

7.Enter the model number of the device being used (up to 255 alpha-numeric characters)

(ex: Mega-Tuner 1000) into the Model field. Either the GUID or Make/Model must be specified within this field.

8.Enter the firmware version used by the target device into the Revision field. Text is required within this field.

The version must be in the format: major.minor.micro (where major, minor, and micro are numbers). An example is: 1.0.0 (revision 1.0.0 of the device firmware).

9.Once you are done creating the profile for the new device, click the New button to assign additional Name and Value property information for association with the new User Defined Device.

When the Add button is selected, the user-defined device is then inserted into the list of discovered physical devices which appears within the lower section of the display (FIG. 72).

When the Cancel button is selected, the addition of the user defined device is aborted,

no amendment to the existing list is made, and the user is returned back to the Manage Device Bindings page.

10.Once you have finished entering your devices, click the Back button (from within the Manage Device Bindings page) and then navigate to the View Discovered Devices page to view the listing of all Dynamic Devices discovered in the system.

How do I write a program that uses Dynamic Device Discovery

These procedures assume the NetLinx developer does not have the Manufacturer device information necessary at the time of the initial setup. For more detailed UI information, refer to the Manage Other Devices - Manage Device Bindings section on page 85. For information on the referenced NetLinx calls, refer to the NetLinx Keywords Help file (found within NetLinx Studio).