NetLinx Security within the Web Server

5.Select either the Control or Emulate option.

FIG. 47 Control/Emulate dialog

To Control a device means that the program generates messages which appear to a specified device to have come from the Master. The options in this frame specify the <D:P:S> combination for the device to be controlled.

To Emulate a device means that the program generates messages which appear to the Master to have come from a specified <D:P:S> combination (real or fictitious). The options in this frame specify the <D:P:S> combination for the device to be emulated.

Selecting this option adds a Push button with the Channel Code section of this page.

6.Enter a System Number, Device Number, and Port Number into the appropriate fields. These values correspond to the device to be controlled, whether real or fictitious.

The Device, Port, and System value ranges are 1 - 65535.

7.Within the Channel Code section, enter a valid Channel number to emulate Channel messages (i.e., Push/ Release, CHON, and CHOFF) for the specified <D:P:S>.

The Channel number range is 1 - 65535.

8.Select the On or Off buttons to Emulate Channel ON (CHON) and Channel OFF (CHOFF) messages for the specified <D:P:S>.

9.Select the Push button to Emulate a push/release on the channel specified. You can click and hold down the Push button to see how the device/Master responds to the push message.

10.Within the Level Code section, enter a valid Level number and Level data value for the specified <D:P:S> and press the Send button to transmit this data.

The Level number range is 1 - 65535.

The list below contains the valid Level data types and their ranges:

56

NI-3101-SIG Signature Series NetLinx Integrated Controller

Page 66
Image 66
AMX NI-3101-SIG manual Select either the Control or Emulate option