NetLinx Security within the Web Server

Diagnostic Configuration Dialog (Cont.)

Feature

Description

 

 

NetLinx Notification Types:

All Notifications: Enables (selects) every notification field.

Online/Offline Messages: Generates a message with a change in the target device’s online/offline status.

Configuration Messages: Generates a message with a change in the target device’s configuration.

Input Channel Changes: Generates a message with an input channel change (i.e. Push/Release) in the target device.

Output Channel Changes: Generates a message with an output channel change (i.e. CHON/CHOFF) in the target device.

Feedback Channel Changes: Generates a message with a feedback channel change in the target device.

Level Changes From Device: Generates a message with a level channel change from the target device.

Level Changes To Device: Generates a message with a level channel change to the target device.

String From Device: Generates a message with a string from the target device.

String To Device: Generates a message with a string sent to the target device.

Command From Device: Generates a message with a command from the target device.

Command To Device: Generates a message with a command to the target device.

Status Messages: Generates a message with a change in the target device’s status.

Custom Events From Device: Generates a message with a custom event occurring from the target device.

5.Remove a diagnostic filter by clicking the Modify button below it (from the Diagnostics dialog), then pressing the Remove button to delete this filter from the Diagnostics dialog.

Once a Preset is assigned to a specific Diagnostic filter "slot" (up to 8), its System:Device:Port fields are greyed-out, and can’t be modified unless the Preset in that slot is removed and replicated with new information within these fields.

To modify a Diagnostic filter’s information (such as System/Device/Port):

Navigate to an empty Diagnostic filter slot and click the Modify button below the filter. Select a previously unused Preset and store it with a new name.

Click the Remove button to remove this duplicate Preset from the specific filter slot.

Re-open the empty slot by clicking the Modify button, select the duplicated Preset and click Recall.

 Change the necessary information (such as the System/Device/Port), then save it as the original Preset name, and click the Update button.

6.Use the Incoming Message field to view all the internal system diagnostic messages that are generated by a NetLinx Master controller. This message field is a text box, where the text within it may be selected and then copied or pasted for storage.

60

NI-3101-SIG Signature Series NetLinx Integrated Controller

Page 70
Image 70
AMX NI-3101-SIG manual Feature Description