NetLinx Security within the Web Server

Selected device

NetLinx Notification types

Device Configuration

dialog

FIG. 48 Diagnostics dialog (showing modify popup)

Setting up and removing a Diagnostic Filter

1.Setup a diagnostic filter by scrolling down the page and clicking the Modify button below the first empty column. This action opens the Device Configuration dialog as a secondary popup window.

Up to 8 concurrent diagnostic filter slots can be simultaneously active using any eight of the 10 available user-configurable Presets available through the Device Configuration dialog.

2.Configure a diagnostic filter using the parameters available within the Diagnostic Configuration dialog.

The Diagnostic Configuration dialog allows you to select both the notifications you wish to receive and the target devices (within the Online Tree) for these notifications. Several different types of asynchronous notifications can be selected for a device:port:system (D:P:S) combination. Each notification type is represented by a column in the table. All messages are displayed in the Notifications tab of the Output Display window within NetLinx Studio v 2.4.

3.A user can choose to either store these selections to a profile or recall a previously stored profile configuration by either:

Select an open Preset number entry from within Presets drop-down list. Make all desired notification selection and press the Store button. Pressing this button opens a popup field labeled Explorer User Prompt - Preset Name?, intended for entering the name associated with this new Preset.

Press OK to return to the previous Device Configuration popup dialog.

Click Cancel to exit this popup and return to the previous dialog box without making any changes.

58

NI-3101-SIG Signature Series NetLinx Integrated Controller

Page 68
Image 68
AMX NI-3101-SIG manual Setting up and removing a Diagnostic Filter, Diagnostics dialog showing modify popup