Configuration and Firmware Update

Communicating with the NI Device via an IP

Whether the on-board Master’s IP Address was Static Set (Set IP Info) or Dynamically obtained (Get IP Info), use the IP Address information from the Network Addresses dialog to establish communication via the LAN- connected Integrated Controller.

1.From your PC, launch NetLinx Studio 2.

2.Obtain the IP Address of the Master from the System Administrator. If you still do not have an IP Address, follow the steps outlined in either the Obtaining the Master’s IP Address (using DHCP) section on page 23 or Assigning a Static IP to the NetLinx Master section on page 24.

3.Select Settings > Master Communication Settings from the Main menu to open the Master Communication Settings dialog (FIG. 23).

FIG. 23 Master Communication Settings dialog

4.Click the Communications Settings button to open the Communications Settings dialog (FIG. 24).

FIG. 24 Communications Settings dialog

5.Click on the NetLinx Master radio button to indicate you are working with a NetLinx Master, and click on the TCP/IP radio button to indicate a connection to the Master via an IP Address.

6.Click the Edit Settings button (on the Communications Settings dialog) to open the TCP/IP Settings dialog (FIG. 25). This dialog contains a series of previously entered IP Address/URLs and their associated names, all of which are stored within NetLinx Studio and are user-editable.

26

NI-3101-SIG Signature Series NetLinx Integrated Controller

Page 36
Image 36
AMX NI-3101-SIG manual Communicating with the NI Device via an IP, Communications Settings dialog