Appendix G: Troubleshooting

Appendix G: Troubleshooting

Datacryptor Ethernet User Manual

Appendix G: Troubleshooting

This appendix is provided to aid you in determining basic problems with your Thales Datacryptor Ethernet unit. If you cannot resolve the problem using this troubleshooting guide, please contact Thales customer support.

Possible Problems and Solutions

The troubleshooting information in this section is grouped into the following categories: logging in, configuration and traffic flow. Within each category you will find a list of symptoms and possible solutions.

Logging In

Symptom

Explanation and Possible Solutions

Boot Process Fails

Contact Thales support for advice

 

 

Administrator password is

Contact Thales for service

forgotten or lost

 

 

 

Not able to connect to the CLI

Re-boot the unit

 

Log out of the Element Manager application.

 

Check the Baud rate settings are set to:

 

115200, 8, N, 1

 

 

Not able to log in to the Front

Verify the password

Panel Viewer

 

 

 

Configuration

Symptom

Explanation and Possible Solutions

Datacryptor does not recognize

Verify the IP address using the Element Manager (see The

its new IP address

IP Management tab section above). Correct the IP address

 

if necessary, save the configuration, and then reboot the

 

Datacryptor.

 

 

The management workstation

Verify that the network connection to the management

can’t communicate with the

port is in place (see the Connect the Cables section

Datacryptor

above).

 

Check the management interface default gateway

 

configuration. Assign a default gateway if the

 

management workstation is on a different subnet than

 

the Datacryptor’s management port.

 

 

Datacryptor is not sending

Ensure that SNMP traps are enabled.

SNMP objects to the

Verify that the management workstation’s IP address is

management workstation

configured as the SNMP trap host address.

 

See the Configuring SNMP section.

 

 