Operations during Serial Code Loading

Datacryptor Ethernet User Manual

Appendix B: Loading Datacryptor Unit Software

3.Select the COM port that the Datacryptor is connected to, using the pull down menu. This is COM1 by default.

4.If the Datacryptor application is already running, you may choose the Ethernet radio button. Enter the IP address in the field next to the Ethernet radio button. Ethernet is faster than Serial for loading code.

5.If the status messages that are generated by the Image Loader utility during the session are not to be saved, clear the check box marked Save Log of Events.

6.Ensure that the Datacryptor is connected to the selected COM port, and that the power is on. If the Ethernet radio button is selected, use a command window to check that the IP address that you have entered responds to Ping requests.

7.Click the Start Upgrade button.

Note: The Image Loader utility will operate differently depending on whether you are using a serial or an Ethernet connection. Please use one of the next two sections, as appropriate to your type of connection.

Operations during Serial Code Loading

If you are using Ethernet loading, please refer to the next section.

1.The Image Loader will try to initialize communications with the Datacryptor. This will take a short time if the Datacryptor has no application loaded; the administrator may be prompted to remove the power and re-power up the Datacryptor. It is best to power down the unit by removing the mains power cable from the Power Supply Unit.

2.The message ’Current Bootstrap version xx.xx.xxxx‘ will be displayed in the status window when the Image Loader has successfully started talking to the bootstrap program in the Datacryptor.

3.After loading and re-initializing the bootstrap, a prompt will be given to select the Image Loader file (.ilf file) containing the Datacryptor application image (e.g. dc2k.ilf). Select the file and click OK. Image Loader files may also contain signed ACE images.

1270A450-005 - June 2008

Page 89

Page 89
Image 89