THALES

Appendix I: Log and SNMP Trap Numbers

Datacryptor Ethernet User Manual

 

 

 

 

 

 

 

Log Type

Code

Trap

Severity

Message

Information

 

 

No.

 

 

 

 

 

 

 

 

 

 

Audit

75

762

Critical

Primary mode reboot: KAT

The encryption algorithm

 

 

 

 

test failure

failed a "Known Answer

 

 

 

 

 

Test" (KAT) and has

 

 

 

 

 

caused the unit to reboot

 

 

 

 

 

to attempt to recover.

 

 

 

 

 

 

Audit

76

763

Critical

Secondary mode reboot: KAT

The encryption algorithm

 

 

 

 

test failure

failed a "Known Answer

 

 

 

 

 

Test" (KAT) and has

 

 

 

 

 

caused the unit to reboot

 

 

 

 

 

to attempt to recover.

 

 

 

 

 

 

Audit

77

764

Major

Hot Standby reboot: FPGA

Hot standby unit has

 

 

 

 

stats mismatch

detected a possible

 

 

 

 

 

problem with the

 

 

 

 

 

encryption device and has

 

 

 

 

 

caused the unit to reboot

 

 

 

 

 

to attempt to recover.

 

 

 

 

 

 

Audit

78

765

Major

Hot Standby reboot: No

Hot standby unit may

 

 

 

 

response from Private CR

have detected problem

 

 

 

 

 

with Host (Private) port

 

 

 

 

 

Ethernet interface which

 

 

 

 

 

appears to have stopped

 

 

 

 

 

responding and has

 

 

 

 

 

caused the unit to reboot

 

 

 

 

 

to attempt to recover

 

 

 

 

 

 

Audit

79

766

Major

Hot Standby reboot: No

Hot standby unit may

 

 

 

 

response from Public CR

have detected problem

 

 

 

 

 

with Network (Public) port

 

 

 

 

 

Ethernet interface which

 

 

 

 

 

appears to have stopped

 

 

 

 

 

responding and has

 

 

 

 

 

caused the unit to reboot

 

 

 

 

 

to attempt to recover

 

 

 

 

 

 

Audit

80

767

Major

Hot Standby reboot: Failed to

Hot Standby unit:

 

 

 

 

change IP address

changing of an IP address

 

 

 

 

 

appears to have failed and

 

 

 

 

 

has caused the unit to

 

 

 

 

 

reboot to attempt to

 

 

 

 

 

recover

 

 

 

 

 

 

Audit

81

768

Major

Detected Primary failure: No

Secondary unit has

 

 

 

 

response from Public virtual

detected Primary unit

 

 

 

 

IP address

failure on Network (public)

 

 

 

 

 

port side

 

 

 

 

 

 

Audit

82

769

Major

Detected primary failure: No

Secondary unit has

 

 

 

 

response from Private virtual

detected Primary unit

 

 

 

 

IP address

failure on Host (private)

 

 

 

 

 

port side

 

 

 

 

 

 

Audit

83

770

Major

Primary: Response back from

Hot standby: primary unit

 

 

 

 

Public virtual IP address

has detected itself,

 

 

 

 

 

probable configuration

 

 

 

 

 

error on public side

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 126

 

 

 

 

THALES

Page 126
Image 126
Angenieux 1270A450-005 user manual Appendix I Log and SNMP Trap Numbers, Datacryptor Ethernet User Manual, Thales