Datacryptor Ethernet User Manual | Appendix I: Log and SNMP Trap Numbers |
Log Type | Code | Trap | Severity | Message |
|
| No. |
|
|
|
|
|
|
|
Error | 14 | 122 | Major | Alarm condition: movement |
(Hardware) |
|
|
| alarm activated |
Error | 15 | 122 Major | Alarm condition: |
(Hardware) |
|
| temperature alarm activated |
Error | 16 | 122 Major | Alarm condition: erase |
(Hardware) |
|
| button activated |
Error | 17 | 122 Major | Alarm condition: battery low |
(Hardware) |
|
|
|
Error | 18 | 122 Major | Alarm condition: secure |
(Hardware) |
|
| memory was erased |
Error | 1 | 121 | Minor | Random no. gen. fault clear |
(Hardware |
|
|
|
|
cleared) |
|
|
|
|
|
|
|
|
|
Error | 2 | 121 | Minor | Real time clock fault clear |
(Hardware |
|
|
|
|
cleared) |
|
|
|
|
|
|
|
|
|
Error | 3 | 121 | Minor | RAM fault cleared |
(Hardware |
|
|
|
|
cleared) |
|
|
|
|
|
|
|
|
|
Error | 4 | 121 | Minor | Encrypt Clock Now in Range |
(Hardware |
|
|
|
|
cleared) |
|
|
|
|
Information
Unit recovered from alarm and noted movement alarm had been activated: it will be necessary to reboot the unit. If alarm persists contact Thales esecurity support
Unit recovered from alarm and noted temperature alarm had been activated: it will be necessary to reboot the unit. If alarm persists contact Thales esecurity support
Unit recovered from alarm and noted erase button alarm had been activated: it will be necessary to reboot the unit. If alarm persists contact Thales esecurity support
Unit recovered from alarm and noted that the battery low alarm had been activated: it will be necessary to reboot the unit. If alarm persists contact Thales
Unit recovered from alarm and noted intrusion detection alarm had been activated: it will be necessary to reboot unit. If alarm persists contact Thales
Random number generator "fault" cleared
Real time clock fault cleared
RAM fault cleared
Encrypt clock fault cleared
Page 107 |