Installation and Operator’s Manual Page 30 of 63
(PVI-3600-OUTD-UK-F-W Rev.: 1.0)
2) Install suitable watertight connectors to the AURORA enclosure
3) Terminate the wires labeled + and – in the same input section
terminal blocks of AURORA Input 1.
4) Connect the cable + to the terminal block labeled +
5) Connect the cable – to the terminal block labeled –
6) Tighten the screw to a torque of 0.6Nm (5.3 in-lbs.)
7) Make the proper connections of the cables to the Wind Interface
Box. The + wire must be connected to the positive terminal of the
Wind Interface box, the – wire must be connected to the negative
terminal of the Wind interface box.
8) Verify th at all connections have been executed properly and all the
screws are tight.
Step 7/7: Close the side panel
WARNING: Tighten side panel screws with a torque of 1.5 Nm (13.2
in-lbs) to ensure watertight sealing.