Message

Warning

Error

Description

 

 

Type

Type

 

 

 

 

 

 

 

 

 

Wind Low

W001

//

Input Voltage under threshold

 

 

Input OC

//

E001

Input overcurrent

 

 

Wind Low

W002

//

Wind Energy low

 

 

Input OV

//

E002

Input Overvoltage

 

 

Internal Error

//

E003

SW error

 

 

Bulk OV

//

E004

Bulk overvoltage

 

 

Internal Error

//

E005

Communication Error

 

 

Out OC

//

E006

Output overcurrent

 

 

Internal Error

//

E007

IGBT saturation

 

 

Internal Error

//

E008

Bulk undervoltage

 

 

Internal Error

//

E009

Internal Error

 

 

Grid Fail

W003

//

Grid Fail

 

 

Internal Error

//

E010

Bulk Low

 

 

Internal Error

//

E011

Ramp Fail

 

 

DC/DC Fail

//

E012

DcDc error revealed by inverter

 

 

Wrong Mode

//

E013

Wrong Input setting (Single

 

 

 

 

 

 

instead of dual)

 

 

Over

//

E014

Overtemperature

 

 

Temperature

 

 

 

 

 

 

 

Capacitors Fault

//

E015

Bulk Capacitor Fail

 

 

Inverter Fail

//

E016

Inverter fail revealed by DcDc

 

 

Internal Error

//

E017

Start Timeout

 

 

Ground Fault

//

E018

I leak fail

 

 

Internal Error

//

E019

leak Sensor fail

 

 

Internal Error

//

E020

Self test error 1

 

 

Internal Error

//

E021

Self test error 2

 

 

Internal Error

//

E022

Self test error 4

 

 

Internal Error

//

E023

Dc-Injection Error

 

 

Grid OV

W004

//

Grid overvoltage

 

 

Grid UV

W005

//

Grid undervoltage

 

 

Grid OF

W006

//

Grid overfrequency

 

 

Grid UF

W007

//

Grid underfrequency

 

 

Z Grid HI

W008

//

Z Grid out of range

 

 

Internal Error

//

E024

Internal Error

 

 

-------------------

//

E025

Riso low (log only)

 

 

Internal Error

//

E026

VRef Error

 

 

Internal Error

//

E027

VGrid Measures error

 

 

Internal Error

//

E028

FGrid Measures error

 

 

Internal Error

//

E029

ZGrid Measures error

 

 

Internal Error

//

E030

ILeak Measures error

 

 

Internal Error

//

E031

Wrong V Measure

 

 

Internal Error

//

E032

Wrong I Measure

 

 

Internal Error

//

E033

Undertemperature

 

 

 

 

 

 

 

 

 

Page 39
Image 39
Aurora Electronics PVI-3600-OUTD-UK-F-W manual Error Description