Installation and Operator’s Manual Page 53 of 63
(PVI-3600-OUTD-UK-F-W Rev.: 1.0)
2) Verify that the inverter is set in mode Parallel:
- SET IN MODE PARALLEL
A short touch of the key allows to scroll the two options.
In order to confirm the selection, press for longer than 5 sec. the same key.
Press it for a shorter time to come back to the previous display.
3) The “SET BAUD RATE” text and the relevant default speed (which is
19200) will be shown on the display.
4) In order to confirm the BAUD RATE at 19200, is requested to press the
key for longer than 5 sec.,
5) the other options can be visualized if pressing the key for less than 5 sec.
This way the different available BAUD RATEs will be shown.
SET IN MODE
INDEPENDENT
#####
SET IN MODE
PARALLEL
#####
SET BAUD RATE
19200
SET BAUD RATE
9600
SET BAUD RATE
4800
SET BAUD RATE
2400