Installation and Operator’s Manual Page 59 of 63
(PVI-3600-OUTD-UK-F-W Rev.: 1.0)
Description Value
PVI-3600-OUTD-UK-F-W
Nominal input voltage 360Vdc
Minimum input voltage to
connect to the grid 50Vdc
“Absolute Maximum Rating”
for input voltage 600Vdc
Input voltage, MPPT operating
range 50Vdc to 530Vdc
Input voltage, MPPT range at
full power 200Vdc to 530Vdc
Max. operating input current
(Wind MPPT Input) 20Adc
Max. input power
(Wind MPPT Input) 3800 W
DC Ground fault protection Ground fault detection and shut off of
utility-interactive inverter
MPPT configuration Single Wind MPPT , Power Curve is specific to
the Wind Turbine model
As stated above, AURORA Wind performs MPPT on the programmed Wind
turbine power curve and constantly researches the max. input Dc power point. This
process is called MPPT (Maximum Power Point Tracking).
NOTE: If the input current supplied by the Wind Interface Box
connected to the inverter is above the max. value and the input voltage is
within the allowed range, the inverter is not damaged.