Installation and Operator’s Manual Page 36 of 63
(PVI-3600-OUTD-UK-F-W Rev.: 1.0)
LEDs Status Operational Status Remarks
1
Power (Green):
Fault (Yellow):
GFI (Red):
AURORA self-disconnection
during no or low wind
conditions.
Input voltage below 50 Vdc
on the MPPT input
2
Power (Green):
Fault (Yellow):
GFI (Red):
AURORA initialization,
settings loading and waiting
for grid check
Input voltage above 50 Vdc
for the MPPT input . It is a
transition status while
operating conditions are
checked.
3
Power (Green):
Fault (Yellow):
GFI (Red):
AURORA is exporting to grid Standard machine operation
(search of max. power point or
constant voltage).
4
Power (Green):
Fault (Yellow):
GFI (Red):
System insulation device
faulty
Ground leakage found
5
Power (Green):
Fault (Yellow):
GFI (Red):
Malfunction – fault!!! The Fault can be inside or
outside the unit. See the alarm
appearing on the LCD.
6
Power (Green):
Fault (Yellow):
GFI (Red):
Installation phase: AURORA
is disconnected from grid.
During installation, it refers to
set-up of the address for RS-
485 communication.
NOTE: All inverter statuses signaled by the corresponding LED
coming on or blinking, are also identified on AURORA LCD by a
message relating to the operation being carried out or to the defect/fault
found (see following sub-sections).