Installation and Operator’s Manual

Page 36 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

 

 

 

LEDs Status

Operational Status

 

Remarks

 

 

 

1

2

3

4

5

6

Power (Green):

Fault (Yellow):

GFI (Red):

Power (Green):

Fault (Yellow):

GFI (Red):

Power (Green):

Fault (Yellow):

GFI (Red):

Power (Green):

Fault (Yellow):

GFI (Red):

Power (Green):

Fault (Yellow):

GFI (Red):

Power (Green):

Fault (Yellow):

GFI (Red):

AURORA self-disconnection during no or low wind conditions.

AURORA initialization, settings loading and waiting for grid check

AURORA is exporting to grid

System insulation device faulty

Malfunction – fault!!!

Installation phase: AURORA is disconnected from grid.

Input voltage below 50 Vdc on the MPPT input

Input voltage above 50 Vdc for the MPPT input . It is a transition status while operating conditions are checked.

Standard machine operation (search of max. power point or constant voltage).

Ground leakage found

The Fault can be inside or outside the unit. See the alarm appearing on the LCD.

During installation, it refers to set-up of the address for RS- 485 communication.

NOTE: All inverter statuses signaled by the corresponding LED coming on or blinking, are also identified on AURORA LCD by a message relating to the operation being carried out or to the defect/fault found (see following sub-sections).

Page 36
Image 36
Aurora Electronics PVI-3600-OUTD-UK-F-W manual Installation phase Aurora is disconnected from grid