AXIS 250S User’s ManualTroubleshooting 39
Symptoms, Possible Causes and Remedial Actions
Symptoms | Possible causes | Remedial actions |
|
|
|
The AXIS 250S cannot be | The IP address is already being | Run the PING utility (as described above) and follow the appropriate |
accessed from a browser. | used by another device. | recommendations. |
|
|
|
| The IP address is located on a | Run the PING utility (as described above). If you get “no response” or |
| different subnet. | similar, the diagnosis is probably correct. |
|
| In Windows, check that the IP address for your AXIS 250S is on the |
|
| same subnet as your workstation. Exactly how this is done varies from |
|
| one version of Windows to another. See Windows’ help for more |
|
| information. |
|
| If the AXIS 250S and your workstation are on different subnets, you |
|
| will not be able to set the IP address. Contact your network |
|
| administrator. |
| The IP address has changed. | Move the AXIS 250S to an isolated network or to one with no DHCP or |
|
| BOOTP servers. Set the IP address again, using the arp command. |
|
| Access the unit and disable BOOTP and DHCP in the TCP/IP settings. |
|
| Return the unit to the main network. |
|
| Note: The AXIS IP Installer will not work with DHCP running on the |
|
| network. |
| Other networking problems. | Test the network cable by connecting it to some other network device |
|
| and then PINGing that device from your workstation. |
|
| Test the unit’s network interface by connecting a local computer to the |
|
| AXIS 250S, using a standard network cable. A crossover cable is not |
|
| required. |
The Power indicator is not | Faulty power supply. | Verify that you are using an Axis |
constantly lit. |
|
|
The Network indicator | No network connection or | See Other networking problems, above. |
displays red. | faulty cabling. |
|
|
|
|
The Status indicator is | Hardware failure. | Contact your Axis dealer. |
flashing red rapidly. |
|
|
Solid red Video indicator. | Lost video signal. | Check the cabling, the power to the camera and the camera settings. |
The AXIS 250S works | Firewall protection. | Check the Internet firewall with your system administrator. |
locally, but not externally. | Default routers required. | Check if you need to configure the default router settings. |
No video. | No network connection. | Check all connections. |
| Display incorrectly configured | In Display Properties, adjust the color settings to at least |
| on your workstation. | If running more than one video stream, you must use |
|
|
|