Symptoms, Possible Causes and Remedial Actions

Symptoms

Possible causes

Remedial actions

 

 

 

The AXIS 250S cannot be

The IP address is already being

Run the PING utility (as described above) and follow the appropriate

accessed from a browser.

used by another device.

recommendations.

 

 

 

 

The IP address is located on a

Run the PING utility (as described above). If you get “no response” or

 

different subnet.

similar, the diagnosis is probably correct.

 

 

In Windows, check that the IP address for your AXIS 250S is on the

 

 

same subnet as your workstation. Exactly how this is done varies from

 

 

one version of Windows to another. See Windows’ help for more

 

 

information.

 

 

If the AXIS 250S and your workstation are on different subnets, you

 

 

will not be able to set the IP address. Contact your network

 

 

administrator.

 

The IP address has changed.

Move the AXIS 250S to an isolated network or to one with no DHCP or

 

 

BOOTP servers. Set the IP address again, using the arp command.

 

 

Access the unit and disable BOOTP and DHCP in the TCP/IP settings.

 

 

Return the unit to the main network.

 

 

Note: The AXIS IP Installer will not work with DHCP running on the

 

 

network.

 

Other networking problems.

Test the network cable by connecting it to some other network device

 

 

and then PINGing that device from your workstation.

 

 

Test the unit’s network interface by connecting a local computer to the

 

 

AXIS 250S, using a standard network cable. A crossover cable is not

 

 

required.

The Power indicator is not

Faulty power supply.

Verify that you are using an Axis PS-K power supply.

constantly lit.

 

 

The Network indicator

No network connection or

See Other networking problems, above.

displays red.

faulty cabling.

 

 

 

 

The Status indicator is

Hardware failure.

Contact your Axis dealer.

flashing red rapidly.

 

 

Solid red Video indicator.

Lost video signal.

Check the cabling, the power to the camera and the camera settings.

The AXIS 250S works

Firewall protection.

Check the Internet firewall with your system administrator.

locally, but not externally.

Default routers required.

Check if you need to configure the default router settings.

No video.

No network connection.

Check all connections.

 

Display incorrectly configured

In Display Properties, adjust the color settings to at least 16-bit color.

 

on your workstation.

If running more than one video stream, you must use 32-bit color.

 

 

 