![Reviewing Set Points](/images/new-backgrounds/77250/7725021x1.webp)
Gourmet Oven | Operation |
•If the hold temperature has been turned off, the oven will sound an audible alert when the cook time reaches zero. This alarm will sound until the “START/STOP” button is pressed.
•If the hold temperature has been set, the controller will regulate the temperature to the desired hold temperature. Once the hold temperature has been achieved, a count up timer will be initiated to track the length of time in the hold mode. The display will alternately show “HOLD”, actual oven temperature and hold elapsed time. The control will stay in the hold mode until the “START/STOP” button is pressed again.
Reviewing Set Points
During the cooking cycle any programmed cooking parameter can be displayed. Press the “SELECT” button until the desired parameter light turns on. The display will show the value of the set point for five
(5) seconds. Reviewing set points during a cooking cycle will not alter them or interrupt the cooking cycle.
Changing Set Points During Cooking
1.Push the “START/STOP” momentarily. The “CYCLE ON” light will flash and the control will go into pause. In this mode the control regulates at the
2.Change the cooking parameters by pressing the “SELECT” button until the desired indicator light turns on. The display will show the
3.Press the “UP” and “DOWN” buttons to change the setting as desired.
4.Resume the cooking cycle by press the “START/STOP” button. The “CYCLE ON” light will come on indicating that the cooking cycle has resumed.
Canceling the Cooking Cycle
Press and hold the “START/STOP” button until the “CYCLE ON” light turns off. (“STOP” will be displayed).
Power Failure During The Cooking Cycle
The control will suspend operation retaining set points and cycle times. When power is restored, operation will resume where left off when the power failed.
Probe (Thermocouple) Diagnostics
If the probe (thermocouple inside the oven) stops working, the control will cancel the cooking cycle and the display will show “PROB”.
If the probe temperature goes below 50° F (10° C.) or if the controller fails, the display will show “EEEE” and the controller will go into “STOP” mode.
Important Instruction
A Malfunction Warning Light is mounted on the control unit front panel. This light illuminates when an overtemperature condition occurs within the Control Unit assembly. If this light goes on, place the POWER ON/POWER OFF switch in the POWER OFF position and contact an authorized BKI service agent for corrective action.
9