Servicing Information

RS232 / V.24 Null-Modem Cable

DB25 MALE

 

 

 

DB25 MALE

 

1

Shield

Shield

1

 

 

2

Transmitted Data

Received Data

3

 

 

3

Received Data

Transmitted Data

2

 

 

4

Request To Send

Data Set Ready

6

 

 

6

Data Set Ready

Request To Send

4

 

 

20

DTE Ready

Received Line Signal Detector (CD)

8

 

 

7

Signal Ground

Signal Ground

7

 

 

8

Received Line Signal Detector (CD)

DTE Ready

20

 

 

15

Transmit Timing DCE Source

Receiver Timing DCE Source 17

 

17

Receiver Timing DCE Source

Transmit Timing DCE Source

15

24

Transmit Timing DTE Source

Transmit Timing DTE Source

24

Figure C-12 RS232 / V.24 Null-Modem Cable

The connecting cable must be a shielded cable.

This cable is needed when it is necessary to connect two units back-to-back and a set of modems is not available. Note that this cable specifies DB25 connectors on each end to allow direct connection to the link interface connector on each unit. The link speed must be defined for each of the two units.

88

Page 94
Image 94