Blodgett RE Series manual Installation, Gas Connection, Gas Hose Restraint

Models: RE Series

1 53
Download 53 pages 32.67 Kb
Page 17
Image 17
GAS HOSE RESTRAINT

Installation Manual background

Gas Connection

GAS HOSE RESTRAINT

If the oven is mounted on casters, a commercial flexible connector with a minimum of 3/4” (1.9 cm) inside diameter must be used along with a quick connect device.

The restraint, supplied with the oven, must be used to limit the movement of the unit so that no strain is placed upon the flexible connector. With the restraint fully stretched the connector should be easy to install and quick connect.

The restraint (ie: heavy gauge cable) should be 1,000 lb. (453 kg) test load and should be attached without damaging the building. DO NOT use the gas piping or electrical conduit for the attachment of the permanent end of the restraint! Use anchor bolts in concrete or cement block. On wooden walls, drive hi test wood lag screws into the studs of the wall.

1.Mount the supplied bracket to the leg bolt just below the gas inlet. See Figure 11.

2.Attach the clip on restraining cable to the mounting bracket.

Back of Oven

Restraint Cable

Bracket

Double stacked unit shown. Use the same procedure for single units with 25” (64 cm) legs.

Figure 11

Manual background WARNING!!

If the restraint is disconnected for any reason it must be reconnected when the oven is returned to its original position.

U.S. and Canadian installations

The connector must comply with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors For Moveable Gas Ap- pliances CAN/CGA-6.16-M87and a quick discon- nect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 or Quick Disconnect For Use With Gas Fuel CAN 1-6.9. Adequate means must be provided to limit the movement of the appliance

without depending on the connection and the quick disconnect device or its associated piping.

Australia and general export installations

The restraint and quick connect must conform with Local and National installation standards. Lo- cal installation codes and/or requirements may vary. If you have any questions regarding the prop- er installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local distributor, please call the Blodgett Oven Company at 0011-802-860-3700.

13

Page 17
Image 17
Blodgett RE Series manual Installation, Gas Connection, Gas Hose Restraint, U.S. and Canadian installations