Bosch Appliances 28i junior Servicing Clearances Vented Compartment, Boiler Location Clearances

Models: 28i junior 24i junior

1 62
Download 62 pages 24.83 Kb
Page 14
Image 14
SERVICING CLEARANCES

SERVICING CLEARANCES

VENTED COMPARTMENT

Using 100mm flue kit 1080mm Using 125mm flue kit - 1110mm

INSTALLATION

PRE -

VENTILATION FREE COMPARTMENTS

INSTALLATION CLEARANCES

Ventilation Free Compartments Installation Clearances

The suggested total unventilated compartment minimum clearances are:

Side

Above

Below

Front (to removable door)

 

 

 

 

400mm

170mm approx.

200mm

100mm

 

(30mm above

 

 

 

the elbow)

 

 

(Note: Top and bottom clearances must not be reduced below these values as they are the minimum required for servicing).

If Side Clearances are Reduced

 

If total side clearance is

Then overall height clearances

OR

Front clearance (to removable

 

 

reduced to:

must be increased to (approx):

door) must be increased to:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350mm

441mm

 

129mm

 

 

300mm

523mm

 

161mm

 

 

 

 

 

 

 

 

250mm

617mm

 

200mm

 

 

200mm

727mm

 

243mm

 

 

 

 

 

 

 

 

150mm

856mm

 

295mm

 

 

100mm

1012mm

 

358mm

 

 

 

 

 

 

 

 

50mm

1202mm

 

434mm

 

 

 

 

 

 

 

If Front Clearance is Reduced

 

 

 

 

 

 

 

 

If front clearance (to

 

Then overall height clearances

 

 

 

Total side clearance must be

 

 

OR

removable door) is

 

must be increased to (approx):

 

 

increased to:

 

 

 

 

 

 

reduced to:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50mm

511mm

 

 

 

505mm

25mm

596mm

 

 

 

569mm

BOILER LOCATION &

CLEARANCES

This boiler is only suitable for installing internally within a property at a suitable location onto a fixed, rigid non-combustible surface at least the same size as the boiler and capable of support- ing the boiler weight.

COMPARTMENTS:

Follow the requirements of B S6798 and BS5440 Part 2 and note:

Minimum clearances must be maintained

An access door is required to install, service and maintain the boiler and any ancilliary equipment.

If fitting the boiler into an airing cupboard use a non-combustible perforated material (maximum hole sizes of 13mm) to separate the boiler from the airing space.

BOILER CLEARANCES:

The diagram opposite shows the minimum space required to install and service the boiler.

If a boiler is installed in a compartment with clearances less than shown in the tables oppo- site, ventilation is required. Refer to tables below for ventilation requirements.

24 & 28 kW

Vent

To room or

Direct to

position

internal space

outside

 

 

 

High

Minimum free

Minimum

level

area 122 cm2

free area

 

 

61 cm2

 

 

 

Low

Minimum free

Minimum

level

area 122 cm2

free area

 

 

61cm2

 

 

 

BOILER CLEARANCES - UNVENTILATED COMPARTMENTS:

The tables opposite show the options for the minimum space required to install and service the boiler inside an unventilated compartment.

13

BOILER LOCATION & CLEARANCES

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior 8 716 107 336b (11/05)

Page 14
Image 14