INSPECTION AND SERVICE
E
|
| COMBUSTION TESTING MUST BE CARRIED | |
|
| OUT BY A COM PETE NT PE R SON . IT M UST | |
|
| NOT BE ATTEMPTED UNLESS THE PERSON | |
|
| CARRYING OUT THE COMBUSTION CHECK | |
|
| I S E Q U I P P E D W I T H A C O M B U S T I O N | |
|
| ANALYSER CONFORMING TO BS 7927 AND | |
|
| IS COMPETENT IN IT’S USE. | |
|
| IMPORTANT: IF THE JOINT | |
|
| BETWEEN THE AIR/GAS MANIFOLD | |
|
| AND THE HEAT EXCHANGER IS | |
|
| DISTURBED THE SEALING GASKET | |
| 1 | MUST BE REPLACED. | |
| B | To Clean the Heat Exchanger | |
| A | 1 | With outer case and base panel removed and |
|
|
| the power isolated from the appliance, |
|
|
| remove the cover panel (A) by removing the |
|
|
| retaining screw (B). |
|
| 2 | Remove clip (C) from gas valve outlet. |
|
|
| Pull gas adjustment assembly (D) free from |
|
|
| the plastic connection on the gas valve. |
|
|
| Pull gas adjustment assembly (D) forward to |
|
|
| clear case. |
|
| Removing Siphon | |
|
| 3.1 | Undo plastic nut (E) on the siphon outlet. |
|
|
| Drop condensate tube away from siphon. |
|
| 3.2 | Remove hose (F). |
|
| 3.3 | Remove siphon |
|
| Siphon | |
|
|
| The siphon body is transparent so contents |
|
|
| can be examined for any blockage. |
|
|
| If necessary flush with clean water. |
3.1 | 3.2 |
| 3.3 |
| F |
| SERVICING SPARES& |
|
|
|
2
D
C
38
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior 8 716 107 336b (11/05)
INSPECTION AND SERVICE