WALL
189mm
93mm
Edge of case
200mm
INSTALLATION
(250mm min)
Turret | Clamp | Flue |
23
FLUE INSTALLATION
HORIZONTAL FLUE (60/100mm diameter)
For vertical flues and 80/125mm horizontal flues, please refer to separate instructions supplied with the flue kit.
NOTE: to ease the assembly of flue components, apply silicone lubricant to sealing surfaces.
The instructions for the 60/100mm diameter flue are shown below.
MEASURING THE FLUE (Standard Flue): Measure from the outside wall to the centre line of the flue turret.
Subtract 93mm from the length L to give the correct dimension to the flue elbow connection.
The terminal section should be cut to this dimension, however it must not be cut shorter than 250mm.
After cutting, the end must be square and free from burrs to prevent damage to the flue seals.
FLUE INSTALLATION
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior 8 716 107 336b (11/05)