A# Perimeter O/C
This item determines if this area can send
Perimeter
Opening
and
Closing
reports to the central station.
Modem Format
reporting is required.
A
Perimeter
Opening
report refers to the panel sending an
Opening
report when the area is disarmed after
being in a perimeter armed state. A
Perimeter
Closing
report refers to the panel sending a
Closing
report
when the area is perimeter armed.
The area can be perimeter armed using either the perimeter instant, or perimeter delayed arming options. In these
cases, the area is only partially armed and is considered in a disarmed state for the following:
Account
Opening
and
Closing
reports and RAM II programming.
Default: No
Selection: Yes or No
Yes This area can send
Perimeter
Opening
and
Closing
reports.
Whether
Perimeter
Opening
and
Closing
reports for a particular user are sent or not depends on
the user’s authority level. If a passcode is required to arm or disarm, and the Authority Lvl Assign
program item L## Perimeter O/C is disabled for the Authority Level,
Perimeter
Opening
and
Closing
reports are disabled for that user. See the User Interface, Authority Lvl Assign section of the
program, L## Perimeter O/C prompt.
Note:
If a passcode is not required for perimeter arming or disarming and this item is YES, the area sends
Perimeter Opening and Closing reports. In this case, the report is sent without User ID.
Opening/Closing Window does not affect this report: Windows do not prevent
Perimeter
Opening
and
Closing
reports from being sent.
There are no reports for Perimeter Partial arming (Command 8).
No This area can not send
Perimeter
Opening
and
Closing
reports.
Even if L## Perimeter O/C is Enabled for the authority level of the passcode used to perimeter arm or
disarm the area, reports are not sent when this item is programmed NO.
A# Disable O/C in Window
This item determines if opening and closing activity is reported when it occurs inside an Opening or Closing
window as programmed in O/C Windows.
Reports are always logged and printed on a local printer, if installed.
Default: Yes
Selection: Yes or No
Yes Do not send
Opening
and
Closing
reports to the central station if they occur inside an active
window.
If an
Opening
or
Closing
report occurs outside of a window, send it with an early or late modifier.
See O/C Windows.
The active window must be a closing window for
Closing
reports. It must be an opening window
for
Opening
reports.
No Send
Opening
and
Closing
reports to the central station even when they occur inside a
programmed window. If an opening or closing occurs outside of the appropriate window, it reports
but does NOT have an early or late modifier.
If you want to monitor all opening and closing activity, but you also want to use features provided
by Opening and Closing Windows, program this item to NO, and program appropriate O/C