D9112B | Program Entry Guide | 11.0 Holiday Indexes EN | 94
Bosch Security Systems | 2/04 | 74-06145-000-D
S## Holiday 3
If no Holiday Index is selected, the Sked operates
regardless of any holiday.
Default: No
Selection: Yes or No
Yes Use Holiday Index 3 with this Sked.
No Do not use Holiday Index 3 with this
Sked.
S## Holiday 4
If no Holiday Index is selected, the Sked operates
regardless of any holiday.
Default: No
Selection: Yes or No
Yes Use Holiday Index 4 with this Sked.
No Do not use Holiday Index 4 with this
Sked.
This programming module has two sections:
Add/Change/Delete and View Holidays. Use the
Add/Change/Delete section to program the Holiday
Indexes. The View Holiday section is a “view only”
section provided for your convenience. Use View
Holidays to review the dates programmed in the
Holiday Indexes.
11.1 Add/Change/Delete
Use this section to program the dates for each of the
Holiday Indexes. You can program up to four
Holiday Indexes in the D9112. Within each index,
you can select up to 365 dates to be designated as
holidays.
The Holiday Indexes function independently from
each other. The same day can be programmed in all
four schedules. Holiday Indexes are used in
programming O/C Windows, User Access Windows, and
Skeds.
Date
Default: _ _/_ _
Selection: MM/DD
This entry selects the month and day you are
designating as a holiday.
To program a date:
1. Press the two digits representing the month.
2. The cursor advances past the slash (/) in the
display.
3. Press the two digits representing the day of the
month.
4. Press [ENT].
To delete a date:
1. At the Date prompt, enter the month and day
you want to delete and press [ENT].
2. Advance to the
Holiday Index #
that you want
to delete the date from. Change the entry to
NO. Press [ENT].
If you want the date completely removed as a
holiday, it must be programmed NO for all the
Holiday Index
# entries.
Holiday Index 1
Default: No
Selection: Yes or No
Yes Use this date in Holiday Index 1.
No Do not use this date in Holiday Index 1.