D9112B | Program Entry Guide | 10.0 Skeds EN | 88
Bosch Security Systems | 2/04 | 74-06145-000-D
Default Description Sub-prompt Selection
2 S## Area 1
Yes
No
Disarm Area 1.
Do not disarm Area 1.
Disarm Area(s). Entries in the
Disarm Area prompts define the
area(s) this Sked disarms. The Sked
can disarm multiple areas. S## Area 2
Yes
No
Disarm Area 2.
Do not disarm Area 2.
S## Area 3
Yes
No
Disarm Area 3.
Do not disarm Area 3.
S## Area 4
Yes
No
Disarm Area 4.
Do not disarm Area 4.
S## Area 5
Yes
No
Disarm Area 5.
Do not disarm Area 5.
S## Area 6
Yes
No
Disarm Area 6.
Do not disarm Area 6.
S## Area 7
Yes
No
Disarm Area 7.
Do not disarm Area 7.
S## Area 8
Yes
No
Disarm Area 8.
Do not disarm Area 8.
3 Bypass a Point. The entry in the Bypass Point prompt defines the point this Sked bypasses. The point
can be bypassed only if
Bypassable
is YES in the Point Index assigned to the point. The bypass is
reported if
Bypass
reports are enabled in the Point Index assigned to the point. The Sked can bypass one
point regardless of the area’s armed state.
4 Unbypass a Point. The entry in the
Unbypass Point
prompt defines the point this Sked unbypasses.
The Sked can unbypass one point regardless of the area’s armed state. The point can be bypassed only
if Bypassable is YES in the Point Index assigned to the point. The bypass is reported if
Bypass
reports are
enabled in the Point Index assigned to the point.
5 S## Area 1 Yes
No
Unbypass all points in Area
1.
Do not unbypass all points
in Area 1.
Unbypass All Points. The entry in
the
Unbypass All
prompt defines
the area(s) where the Sked
unbypasses all points. The Sked
unbypasses all points in the area,
regardless of how they were
bypassed. This Sked can unbypass
all points in multiple areas.
S## Area 2 Yes
No
Unbypass all points in Area
2.
Do not unbypass all points
in Area 2.
S## Area 3 Yes
No
Unbypass all points in Area
3.
Do not unbypass all points
in Area 3.
S## Area 4 Yes
No
Unbypass all points in Area
4.
Do not unbypass all points
in Area 4.