D9112B | Program Entry Guide | 3.0 User Interface EN | 50
Bosch Security Systems | 2/04 | 74-06145-000-D
L## Master Arm Inst
Master Arm
Default: See
Program Record Sheet
Selection: Blank or E
Blank Disable this function for Authority Level (L##) specified, if this Command Center Function item
requires a passcode (P).
E Enable this function for Authority Level specified. When the passcode is entered at the command
center, the panel checks the authority level. The panel executes the function only in areas where the
passcode is authorized.
Programming in O/C Options
Area O/C
and
Restricted O/C
determines whether
Opening
and
Closing
reports can be generated for a particular area.
Whether
Opening
and
Closing
reports are generated by this user or not depends on the
L##
Area O/C
and
L## Restricted O/C
prompts in Authority Lvl Assign.
Perim Instant
Perimeter Instant Arm [COMMAND] [2]:
This command center function arms all perimeter points (see Point Index
Point Type
) in the area where the
command center is assigned. No entry or exit delays are provided with this arming function.
Default: P
Selection: Blank, E or P
Blank Disable the function panel-wide. Accessing the function using a command, the Command Menu, or
a custom function, displays NO AUTHORITY.
E Enable the function panel-wide. The function can be executed without entering a passcode.
Programming in O/C Options
Perimeter O/C
determines whether
Perimeter
Closing
reports can
be generated for a particular area.
P Passcode required. When the passcode is entered at the command center, the panel checks the
authority level. The panel only arms the area if the passcode is authorized.
0101
0101
0101
Force Arming: If a passcode is not required to arm these functions, all authority levels can force arm. To
disable force arming in an area, enter 0 in FA Bypass Max in the Area Parameters section of the program.