D9112B | Program Entry Guide | 1.0 Panel Wide Parameter EN | 18
Bosch Security Systems | 2/04 | 74-06145-000-D
Ph# Test/Stat Rpt
Default: Blank
Selection: Blank, P, B, or D
See the introduction to Phone Routing for a
description of the selections.
Test
reports and
Status
reports are enabled in the
Skeds section of the program. For
Test
reports, see
Sked Function Code #9. For
Status
reports, see
Sked Function Code #10.
Test
and
Status
reports are identified at the D6500
using the account number for Area 1.
If
Expand Test Rpt in Phone is YES, the
Test
report
includes additional system events, if the panel is
currently in one of these conditions: Prog Access
OK, SDI Failure, Comm Failure, Battery
Missing, Battery Low, Pt Bus Trouble,
AC Failure, Params Bad Cksm, Log
Threshold, Log Overflow, Bad Call to
RAM, and User Tamper.
After a Reset-Bye or disable restart, the panel
checks to see if the following conditions exist. If they
do, the panel sends appropriate reports with the test
report:
Log
,
Log
,
Bad Call to RAM, and
User Tamper. All other system events
are cleared and do not report at test time.
To clear Bad Call to RAM and User Tamper
events, simply contact the panel with RAM II. To
clear Log Threshold and Log Overflow
contact the panel with RAM II and perform a
Receive Log and Set Pointer function from the
Logger menu.
Ph# Diagnostic
Default: Blank
Selection: Blank, P, B, or D
See the introduction to Phone Routing for a
description of the selections.
If a Parameter Checksum Fail (
Parm Cksum Fail)
report is received, the user can silence the panel’s
buzzer, but cannot clear the system trouble display.
To correct a Parameter Checksum Fail condition, re-
load the program into the panel using RAM or the
D5200
Ph# Relay
Default: Blank
Selection: Blank, P, B, or D
See the introduction to Phone Routing for a
description of the selections.
Ph# Skeds
Default: Blank
Selection: Blank, P, B, or D
See the introduction to Phone Routing for a
description of the selections.
Note:
The panel uses Skeds 18 to 49 for opening and closing
windows and Skeds 50 to 64 for User Access
Windows. Routing Skeds activity to a receiver when
using these features can result in excessive receiver
traffic.
Ph# RAM
Default: Blank
Selection: Blank, P, B, or D
See the introduction to Phone Routing for a
description of the selections.
These events are associated with RAM functions.
RAM reports are identified at the D6500 using the
account number for Area 1.
RAM Access Fail may indicate a wrong
passcode when communicating with the panel, or a
valid RAM session was terminated by a means other
than a Good-bye or Reset-bye command. Log
Threshold is programmed in RAM Parameters
Log % Full. Remote Reset indicates a Reset-Bye
command issued from RAM. Bad Call to RAM
indicates that the panel called RAM but was unable
to connect.
Ph# Power/Phone
Default: Blank
Selection: Blank, P, B, or D
See the introduction to Phone Routing for a
description of the selections.