D9112B | Program Entry Guide | 3.0 User Interface EN | 53
Bosch Security Systems | 2/04 | 74-06145-000-D
Watch Mode
Default: E
Selection: Blank, E, or P
Watch Mode [COMMAND] [6]:
This command center function operates only in the
area where the command center is assigned. No
entry or exit delays are provided with this arming
function.
This function provides command center and
optional relay annunciation of faults from points that
are programmed as
Watch Points
in Point Index.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Watch Mode
Default: See
Program Record Sheet
Selection: Blank or E
Watch Mode: See Authority Level Selections in the
introduction to the Authority Lvl Assign programming
module for descriptions of selections.
Perim Partial
Default: E
Selection: Blank, E, or P
This command center function arms only perimeter
points which are not faulted in the area where the
command center is assigned. Entry and exit delays
are provided with this arming function.
This function ignores the
A# FA Bypass Max
entry
in Area Parameters.
No
Closing
report is sent to the central station,
however, a Perimeter Delay event is recorded and
faulted points are identified as “forced” in the event
log.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Perim Partial
Default: See
Program Record Sheet
Selection: Blank or E
Perimeter Partial Arm: See Authority Level Selections
in the introduction to the Authority Lvl Assign
programming module for descriptions of selections.
View Area Stat
Default: P
Selection: Blank, E, or P
View Area Status: This command center function
allows the user to view the armed status of areas
other than the one to which the command center is
assigned. This function shows the following status for
areas where the passcode is authorized: armed,
disarmed, perimeter armed (partial, instant, delayed)
not ready to arm, account armed text, exit delay
text, entry delay text.
L## View Area Stat
Default: See
Program Record Sheet
Selection: Blank or E
View Area Status: See Authority Level Selections in
the introduction to the Authority Lvl Assign
programming module for descriptions of selections.
View Event Mem
Default: E
Selection: Blank, E, or P
View Event Memory [COMMAND] [4] [O]:
View prior alarm and trouble activity that occurred
during the last armed period. The user can view
activity in areas within the
Scope
of the command
center where the function is entered (see Cmd Cntr
Assignment). Event memory is not cleared until the
area is rearmed.
See Command Center Function Selections in the
introduction to the Authority Lvl Assign programming
module for descriptions of selections.
L## View Event Mem
Default: See
Program Record Sheet
Selection: Blank or E
View Event Memory: See Authority Level Selections
in the introduction to the Authority Lvl Assign
programming module for descriptions of selections.