D9112B | Program Entry Guide | 3.0 User Interface EN | 60
Bosch Security Systems | 2/04 | 74-06145-000-D
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Service Walk
Default: See
Program Record Sheet
Selection: Blank or E
Service Walk Test: See Authority Level Selections in
the introduction to the Authority Lvl Assign
programming module for descriptions of selections.
Default Text
Default: P
Selection: Blank, E, or P
Display Default Command Center Text
[COMMAND] [5] [7]: This command center
function affects only the command center address
where the function is entered. This command center
function allows the user to display the non-
customized command center idle text for the area
where the command center is assigned. This may be
helpful in troubleshooting if the service technician or
user cannot remember the area number or meaning
of custom idle text.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Default Text
Default: See
Program Record Sheet
Selection: Blank or E
Display Default Command Center Text: See
Authority Level Selections in the introduction to the
Authority Lvl Assign programming module for
descriptions of selections.
Change Skeds
Default: P
Selection: Blank, E, or P
Change Skeds [COMMAND] [5] [2]: A panel-
wide function that can be executed from any
command center assigned to an area where the user
has authority. Use to make adjustments to Skeds
numbered 1 to 17. See the Security System Owner’s
Guide for operating instructions.
See Command Center Function Selections in the
introduction to the Command Center Functions
programming module for descriptions of selections.
L## Change Skeds
Default: See Training Sheet
Selection: Blank or E
Change Skeds: See Authority Level Selections in the
introduction to the Authority Lvl Assign programming
module for descriptions of selections.
3.5 Authority Level Opening and Closing Options
L## Force Arm
Arm the area to be armed even if the controlled
points are not normal. Points that are not normal are
left out of the system during the arming procedure
and do NOT detect violations. Other points operate
as programmed.
This program item is used in conjunction with
programming for other arming functions. When a
passcode is required to arm, use this program item to
restrict the ability to force arm.
0101
0101
0101
If a passcode is not required to arm using
a particular function, all authority levels can
force arm with that function. To disable
force arming in an area, enter 0 in FA
Bypass Max in the Area Parameters
section of the program.
Default: See
Program Record Sheet
Selection: Blank or E
Blank Force Arming is disabled for users
with the authority level specified if a
passcode is required to arm with the
function used to initiate the force
arming sequence.
E Enable Force Arming for the