66 en Configuration menu

Digital Video Recorder 440/480 Series

 

 

6.5Network

6.5.1TCP/IP

Figure 6.16 Network - TCP/IP

1.Enable DHCP to have the IP address, subnet mask, and default gateway assigned automatically by the network server.

If DHCP is disabled, fill in the IP address, the Subnet mask, the default Gateway, and the Primary DNS server address. If required, change the default HTTP port no. (80) to a new value.

2.Restrict the network Bandwidth limit by entering a value between 256 Kbps and

100 Mbps. If 256 or 512_Kbps is selected, the DVR automatically selects I-frame only video at 1 IPS for transmission over the low bandwidth network connection.

(A video clip is not attached to an e-mail if 256 or 512_Kbps is selected.)

3.Enable the RTSP server to stream live video (for example, to a smart phone). If RTSP is enabled (on), enter a TCP/IP port number (default port 554).

4.ICMP is set to Off by default (ping is not available). Set ICMP to On if you are using Control Center software version 3.34 or lower).

6.5.2Streaming to mobile devices

The Real Time Streaming Protocol (RTSP) feature allows live video streaming over the network.

Attention:

If you enable this feature (RTSP server to On) and the firewall on a ADSL router is opened, anybody can view the cameras. There is no log-on user ID or password to protect a camera live image.

AM18-Q0605 v2.0 2012.04

Installation and Operation manual

Bosch Security Systems

Page 66
Image 66
Bosch Appliances DVR 440, DVR 480 operation manual 5Network, 1TCP/IP, 2Streaming to mobile devices