48 en Operating instructionsDigital Video Recorder 440/480 Series

5.11

Triggers and alarms

Various types of events change the way the unit works. These events are:

an alarm input signal applied to the unit

motion detection in a camera signal

a loss of video from one of the cameras

an internal alert from the unit itself (i.e. disk failure, temperature alarm) The way the unit reacts to events depends on how it is programmed.

An event can cause either a trigger or an alarm. A trigger changes the way the unit works but does not require a response from the user. An alarm also changes the way the unit works but, in addition, usually activates several indicators and requires the user to acknowledge the alarm situation.

The unit reacts to an event in any one of the following ways:

Alarms

A beeper sounds.

A status message is displayed.

An alarm icon is displayed.

The border around a cameo changes color to red.

An alarm or video loss indicator flashes.

An output relay is activated.

Triggers

A motion indicator flashes.

The view modes on the monitors change.

A controllable camera might be moved to a pre-defined position.

Recording behavior changes.

The unit changes the way it operates via pre-defined profiles.

Background events

Triggers and alarms can change background tasks that a user may not notice. Unit responses that are not visible to the user are, for example, a change in recording speed, the activation of the output relay, and event logging. The unit can also be configured to record upon the activation of an alarm input. A trigger may change the way the camera images are displayed on the monitors without requiring intervention.

5.11.1Alarm inputs

If an input causes an alarm

Monitors A and B can switch to a pre-programmed view mode.

Monitor A: The border around the displayed cameos is red. The alarm icon is displayed in the corresponding cameo. An alarm status message is displayed.

Monitor B: Full screen or sequenced display of pre-programmed cameras.

The alarm beeper sounds. The alarm indicators flash.

A controllable camera might be moved to a pre-defined position.

AM18-Q0605 v2.0 2012.04

Installation and Operation manual

Bosch Security Systems

Page 48
Image 48
Bosch Appliances DVR 440, DVR 480 operation manual Triggers and alarms, Alarm inputs