Digital Video Recorder 440/480 SeriesHardware setup en 25
4.6USB connectors
A USB 2.0 connector is located at the rear panel of the unit to which a mouse, for example, can be connected. For convenience, the USB 2.0 port is located on the front of the unit to connect a mouse or USB memory device. (Recording to a
| Figure 4.7 USB connector (on front and on rear) |
4.7 | RS485 port |
Connect Bosch or
–9600 baud
–8 data bits
–1 stop bit
–no parity
–no flow control
Figure 4.8 RS-485 connector
Signal name | Pin number | Description |
|
|
|
TX - | 1 | Data transmission |
|
|
|
TX + | 2 | Data transmission |
|
|
|
GND | 3 | Shield |
|
|
|
Table 4.3 RS485 pin definition
The recommended cable cross section is AWG 28-16 (0.08-1.5 mm2).
Bosch Security Systems | Installation and Operation manual |