Digital Video Recorder 440/480 SeriesHardware setup en 23

4.4RS-232 COM port connections

The RS-232 COM port is used to connect a PC to the unit for service purposes or to connect a Bosch “RS-232 to Bi-Phase Converter”. For service purposes, use a null-modem cable to connect the serial port of the PC to the unit. The Baud rate can be selected in the menu system.

Specifications

Connector type: 9-pole D-type male connector

Maximum input voltage: ±25V

Communicaton protocol: Output signals according EIA/TIA-232-F

Figure 4.5

RS-232 COM port connector

 

 

 

 

 

Signal name

Pin number

Description

 

 

 

 

DCD_in

 

1

Carrier detection signal (not used)

 

 

 

 

RX

 

2

RS-232 receive signal

 

 

 

 

TX

 

3

RS-232 transmit signal

 

 

 

 

N/C

 

4

No connection

 

 

 

System ground

5

System ground

 

 

 

 

N/C

 

6

No connection

 

 

 

 

RTS

 

7

RS-232 request to send signal

 

 

 

 

CTS

 

8

RS-232 clear to send signal

 

 

 

 

N/C

 

9

No connection

 

 

 

 

Table 4.1

RS232 console port socket

 

 

Bosch Security Systems

Installation and Operation manual

AM18-Q0605 v2.0 2012.04

Page 23
Image 23
Bosch Appliances DVR 480, DVR 440 4RS-232 COM port connections, Signal name Pin number Description, Rts, Cts