Network

 

You can connect the VIP XD to a 10/100 Base-T network using a standard UTP category 5

 

cable with RJ45 plugs.

 

X Connect the VIP XD to the network via the ETH socket.

 

Data Interface

 

The bi-directional data interface is used to control units connected to the VIP XD, for example

 

a control panel for dome cameras with motorized lens. The connection supports the RS-232,

 

RS-422 and RS-485 transmission standards.

 

The VIP XD offers the serial interface via the orange terminal block (see Section 8.6 Terminal

 

Block, page 66).

 

The range of controllable equipment is expanding constantly. The manufacturers of the

 

relevant equipment provide specific information on installation and control.

 

 

 

CAUTION!

!

Please take note of the appropriate documentation when installing and operating the unit to

be controlled.

The documentation contains important safety instructions and information about permitted

 

uses.

 

 

 

 

i

NOTICE!

A video connection is necessary to transmit transparent data.

 

 

 

 

Alarm Inputs

 

The VIP XD has four alarm inputs on the orange terminal block (see Section 8.6 Terminal Block,

 

page 66). The alarm inputs are used to connect to external alarm devices such as door

 

contacts or sensors. With the appropriate configuration, an alarm sensor can automatically

 

connect the VIP XD to a particular sender, for example.

 

A zero potential closing contact or switch can be used as the actuator.

 

 

i

NOTICE!

If possible, use a bounce-free contact system as the actuator.

 

 

 

 

X Connect the lines to the appropriate terminals on the orange terminal block (IN1 to IN4)

 

and check that the connection is secure.